Product features:
- High accuracy and reliability with Germany-made chip
- Use of 316L isolation diaphragm and stainless steel case
- Two-wire system standard 4-20mA signal output; customized RS485 signal or HART signal output is available;
- General precision: 0.25 grade, customized 0.1 grade is available
- Multiple process interfaces and electrical interfaces are available for selection
- Multiple pressure types are available for selection
- In-built advanced anti-interference and surge protection circuit
Field of application:
It can be used to measure the pressure, absolute pressure and negative pressure of corrosive gases, liquids and steam in the fields of petroleum, chemical industry, metallurgy, electric power and environmental protection.
Technical parameters:
Range
-100~0~5, 100, 500, 800, 1000kPa; 0~2, 10……10MPa
Pressure type
Differential pressure
Output signal
4~20mA, 4~20mA+HART protocol, 4~20mA+RS485 protocol
Input voltage
8~30V DC
Accuracy
0.1
0.2(0.25)
0.5
Nonlinear repeatability delaying
0.1
0.2(0.25)
0.5
Zero and sensitivity drift
0.01
0.02(0.025)
0.005
Temperature compensation
-10℃~70℃
Work temperature
-20~+85℃
Long-term stability
≤0.1±%FS/year
Response time
<1ms
Overload capacity
200%
Load resistance
R=(U-12.5)/0.02-RD
U=power voltage; RD=internal resistance of power source
Measurement medium
Corrosive media compatible with 316L
Diaphragm material
316L stainless steel, heusler alloy C-276
Case material
1Cr18Ni9Ti
Protection rating
IP67
LONN-7FX Anti-corrosion Differential Pressure Transducer
Download: here
Field of application:
It can be used to measure the pressure, absolute pressure and negative pressure of corrosive gases, liquids and steam in the fields of petroleum, chemical industry, metallurgy, electric power and environmental protection.
Technical parameters:
Range
-100~0~5, 100, 500, 800, 1000kPa; 0~2, 10……10MPa
Pressure type
Differential pressure
Output signal
4~20mA, 4~20mA+HART protocol, 4~20mA+RS485 protocol
Input voltage
8~30V DC
Accuracy
0.1
0.2(0.25)
0.5
Nonlinear repeatability delaying
0.1
0.2(0.25)
0.5
Zero and sensitivity drift
0.01
0.02(0.025)
0.005
Temperature compensation
-10℃~70℃
Work temperature
-20~+85℃
Long-term stability
≤0.1±%FS/year
Response time
<1ms
Overload capacity
200%
Load resistance
R=(U-12.5)/0.02-RD
U=power voltage; RD=internal resistance of power source
Measurement medium
Corrosive media compatible with 316L
Diaphragm material
316L stainless steel, heusler alloy C-276
Case material
1Cr18Ni9Ti
Protection rating
IP67
LONN-7FX Anti-corrosion Differential Pressure Transducer
Download: here